specviewer.org TS 38.331 ASN.1 index CandidateTCI-UL-State-r18

CandidateTCI-UL-State (CandidateTCI-UL-State-r18)

RRC IE · TS 38.331 v19.4.0 (2026-09) · clause 6.3.2

CandidateTCI-UL-State-r18 is an RRC information element of 3GPP TS 38.331 (38331), the 5G NR Radio Resource Control (RRC) protocol.

First seen v18.0.0 (2024-01) · Last changed v18.5.0 (2025-03)

Definition

The IE CandidateTCI-UL-State defines an uplink TCI states configuration.

CandidateTCI-UL-State-r18 ::=           SEQUENCE {
    tci-UL-StateId-r18                      TCI-UL-StateId-r17,
    referenceSignal-r18                     CHOICE {
        ssb-Index                               SSB-Index,
        csi-RS-Index                            NZP-CSI-RS-ResourceId
    },
    pathlossReferenceRS-Id-r18              PathlossReferenceRS-Id-r17                                   OPTIONAL,   -- Need R
    tag-Id-ptr-r18                          ENUMERATED {n0,n1}                                           OPTIONAL,   -- Cond 2TA
    ul-PowerControl-r18                     Uplink-powerControlId-r17                                    OPTIONAL,   -- Cond separateTCI
    ...
}

Candidate change requests of v18.5.0

The CRs whose title or cover names this change, strong and likely matches only.

Fields (7)

FieldDescription
tci-UL-StateId-r18
TCI-UL-StateId-r17
referenceSignal-r18
CHOICE {
Reference signal with which spatial relation information is provided. The field csi-RS-Index refers to one of the NZP-CSI-RS-Resource configured within LTM-TCI-Info , if present. Otherwise, the field csi-RS-Index refers to one of the NZP-CSI-RS-Resource configured outside LTM-TCI-Info (within LTM-Candidate ).
ssb-Index
SSB-Index
The index of a SSB/PBCH block as indicated in ltm-SSB-Config of the LTM candidate that includes this CandidateTCI-UL-State .
csi-RS-Index
NZP-CSI-RS-ResourceId
Indicates an NZP-CSI-RS-Resource of the LTM candidate that includes this CandidateTCI-UL-State .
pathlossReferenceRS-Id-r18
PathlossReferenceRS-Id-r17 · OPTIONAL Need R
Indicates a PathlossReferenceRS of the LTM candidate that includes this CandidateTCI-UL-State and it refers to one of the PathlossReferenceRS configured within LTM-TCI-Info . In this version of the specification, only SSB can be included as reference signal when PathlossReferenceRS is included within a CandidateTCI-UL-State IE.
tag-Id-ptr-r18
ENUMERATED {n0,n1} · OPTIONAL Cond 2TA
since v18.2.0
ul-PowerControl-r18
Uplink-powerControlId-r17 · OPTIONAL Cond separateTCI
since v18.3.0
Indicates the UL power control parameters for PUSCH, PUCCH, and SRS of the candidate that includes this CandidateTCI-UL-State . This field refers to an element in the list configured using uplink-PowerControlToAddModList in the SpCellConfig of the ltm-CandidateConfig in the LTM-Candidate where the ltm-TCI-Info is configured.

Used by (1)

Uses (5)

In the viewer