DRX-ConfigPTM (DRX-ConfigPTM-r17)
DRX-ConfigPTM-r17 is an RRC information element of 3GPP TS 38.331 (38331), the 5G NR Radio Resource Control (RRC) protocol.
Definition
The IE DRX-ConfigPTM is used to configure DRX related parameters for PTM transmission as specified in TS 38.321 [3].
DRX-ConfigPTM-r17 ::= SEQUENCE {
drx-onDurationTimerPTM-r17 CHOICE {
subMilliSeconds INTEGER (1..31),
milliSeconds ENUMERATED {
ms1, ms2, ms3, ms4, ms5, ms6, ms8, ms10, ms20, ms30, ms40, ms50, ms60,
ms80, ms100, ms200, ms300, ms400, ms500, ms600, ms800, ms1000, ms1200,
ms1600, spare8, spare7, spare6, spare5, spare4, spare3, spare2, spare1
}
},
drx-InactivityTimerPTM-r17 ENUMERATED {
ms0, ms1, ms2, ms3, ms4, ms5, ms6, ms8, ms10, ms20, ms30, ms40, ms50, ms60, ms80,
ms100, ms200, ms300, ms500, ms750, ms1280, ms1920, ms2560, spare9, spare8,
spare7, spare6, spare5, spare4, spare3, spare2, spare1
},
drx-HARQ-RTT-TimerDL-PTM-r17 INTEGER (0..56) OPTIONAL, -- Cond HARQFeedback
drx-RetransmissionTimerDL-PTM-r17 ENUMERATED {
sl0, sl1, sl2, sl4, sl6, sl8, sl16, sl24, sl33, sl40, sl64, sl80, sl96, sl112, sl128,
sl160, sl320, spare15, spare14, spare13, spare12, spare11, spare10, spare9,
spare8, spare7, spare6, spare5, spare4, spare3, spare2, spare1
} OPTIONAL, -- Cond HARQFeedback
drx-LongCycleStartOffsetPTM-r17 CHOICE {
ms10 INTEGER(0..9),
ms20 INTEGER(0..19),
ms32 INTEGER(0..31),
ms40 INTEGER(0..39),
ms60 INTEGER(0..59),
ms64 INTEGER(0..63),
ms70 INTEGER(0..69),
ms80 INTEGER(0..79),
ms128 INTEGER(0..127),
ms160 INTEGER(0..159),
ms256 INTEGER(0..255),
ms320 INTEGER(0..319),
ms512 INTEGER(0..511),
ms640 INTEGER(0..639),
ms1024 INTEGER(0..1023),
ms1280 INTEGER(0..1279),
ms2048 INTEGER(0..2047),
ms2560 INTEGER(0..2559),
ms5120 INTEGER(0..5119),
ms10240 INTEGER(0..10239)
},
drx-SlotOffsetPTM-r17 INTEGER (0..31)
}
Fields (28)
| Field | Description |
|---|---|
| drx-onDurationTimerPTM-r17 CHOICE { | Value in multiples of 1/32 ms (subMilliSeconds) or in ms (milliSecond). For the latter, value ms1 corresponds to 1 ms, value ms2 corresponds to 2 ms, and so on. |
| subMilliSeconds INTEGER (1..31) | |
| milliSeconds ENUMERATED { ms1, ms2, ms3, ms4, ms5, ms6, ms8, ms10, ms20, ms30, ms40, ms50, ms60, ms80, ms100, ms200, ms300, ms400, ms500, ms600, ms800, ms1000, ms1200, ms1600, spare8, spare7, spare6, spare5, spare4, spare3, spare2, spare1 } | |
| drx-InactivityTimerPTM-r17 ENUMERATED { ms0, ms1, ms2, ms3, ms4, ms5, ms6, ms8, ms10, ms20, ms30, ms40, ms50, ms60, ms80, ms100, ms200, ms300, ms500, ms750, ms1280, ms1920, ms2560, spare9, spare8, spare7, spare6, spare5, spare4, spare3, spare2, spare1 } | Value in multiple integers of 1 ms. ms0 corresponds to 0, ms1 corresponds to 1 ms, ms2 corresponds to 2 ms, and so on. |
| drx-HARQ-RTT-TimerDL-PTM-r17 INTEGER (0..56) · OPTIONAL Cond HARQFeedback | Value in number of symbols of the CFR where the transport block was received. |
| drx-RetransmissionTimerDL-PTM-r17 ENUMERATED { sl0, sl1, sl2, sl4, sl6, sl8, sl16, sl24, sl33, sl40, sl64, sl80, sl96, sl112, sl128, sl160, sl320, spare15, spare14, spare13, spare12, spare11, spare10, spare9, spare8, spare7, spare6, spare5, spare4, spare3, spare2, spare1 } · OPTIONAL Cond HARQFeedback | Value in number of slot lengths of the CFR where the transport block was received. value sl0 corresponds to 0 slots, sl1 corresponds to 1 slot, sl2 corresponds to 2 slots, and so on. |
| drx-LongCycleStartOffsetPTM-r17 CHOICE { | drx-LongCycle-PTM in ms and drx-StartOffset-PTM in multiples of 1 ms. |
| ms10 INTEGER(0..9) | |
| ms20 INTEGER(0..19) | |
| ms32 INTEGER(0..31) | |
| ms40 INTEGER(0..39) | |
| ms60 INTEGER(0..59) | |
| ms64 INTEGER(0..63) | |
| ms70 INTEGER(0..69) | |
| ms80 INTEGER(0..79) | |
| ms128 INTEGER(0..127) | |
| ms160 INTEGER(0..159) | |
| ms256 INTEGER(0..255) | |
| ms320 INTEGER(0..319) | |
| ms512 INTEGER(0..511) | |
| ms640 INTEGER(0..639) | |
| ms1024 INTEGER(0..1023) | |
| ms1280 INTEGER(0..1279) | |
| ms2048 INTEGER(0..2047) | |
| ms2560 INTEGER(0..2559) | |
| ms5120 INTEGER(0..5119) | |
| ms10240 INTEGER(0..10239) | |
| drx-SlotOffsetPTM-r17 INTEGER (0..31) | Value in 1/32 ms. Value 0 corresponds to 0 ms, value 1 corresponds to 1/32 ms, value 2 corresponds to 2/32 ms, and so on. |