specviewer.org TS 38.331 ASN.1 index PeriodicalReportConfigInterRAT

PeriodicalReportConfigInterRAT

RRC IE · TS 38.331 v19.4.0 (2026-09) · clause 6.3.2, in the ReportConfigInterRAT clause

PeriodicalReportConfigInterRAT is an RRC information element of 3GPP TS 38.331 (38331), the 5G NR Radio Resource Control (RRC) protocol.

First seen v15.3.0 (2018-09) · Last changed v18.1.0 (2024-04)

Definition

PeriodicalReportConfigInterRAT ::=              SEQUENCE {
    reportInterval                                  ReportInterval,
    reportAmount                                    ENUMERATED {r1, r2, r4, r8, r16, r32, r64, infinity},
    reportQuantity                                  MeasReportQuantity,
    maxReportCells                                  INTEGER (1..maxCellReport),
    ...,
    [[
        reportQuantityUTRA-FDD-r16                      MeasReportQuantityUTRA-FDD-r16         OPTIONAL   -- Need R
    ]],
    [[
        includeCommonLocationInfo-r16       ENUMERATED {true}                                              OPTIONAL,   -- Need R
        includeBT-Meas-r16                  SetupRelease {BT-NameList-r16}                                 OPTIONAL,   -- Need M
        includeWLAN-Meas-r16                SetupRelease {WLAN-NameList-r16}                               OPTIONAL,   -- Need M
        includeSensor-Meas-r16              SetupRelease {Sensor-NameList-r16}                             OPTIONAL    -- Need M
    ]],
    [[
        reportQuantityRelay-r17             SL-MeasReportQuantity-r16                                      OPTIONAL    -- Need R
    ]]
}

Fields (10)

FieldDescription
reportInterval
ReportInterval
reportAmount
ENUMERATED {r1, r2, r4, r8, r16, r32, r64, infinity}
Number of measurement reports applicable for eventTriggered as well as for periodical report types
reportQuantity
MeasReportQuantity
The cell measurement quantities to be included in the measurement report. If the field reportQuantityUTRA-FDD is present, the UE shall ignore the value(s) provided in reportQuantity .
maxReportCells
INTEGER (1..maxCellReport)
Max number of non-serving cells/candidate L2 U2N Relay UEs to include in the measurement report.
reportQuantityUTRA-FDD-r16
MeasReportQuantityUTRA-FDD-r16 · OPTIONAL Need R
since v16.1.0
The cell measurement quantities to be included in the measurement report. If the field reportQuantityUTRA-FDD is present, the UE shall ignore the value(s) provided in reportQuantity .
includeCommonLocationInfo-r16
ENUMERATED {true} · OPTIONAL Need R
since v16.5.0
includeBT-Meas-r16
SetupRelease {BT-NameList-r16} · OPTIONAL Need M
since v16.5.0
includeWLAN-Meas-r16
SetupRelease {WLAN-NameList-r16} · OPTIONAL Need M
since v16.5.0
includeSensor-Meas-r16
SetupRelease {Sensor-NameList-r16} · OPTIONAL Need M
since v16.5.0
reportQuantityRelay-r17
SL-MeasReportQuantity-r16 · OPTIONAL Need R
since v17.0.0

Used by (1)

Uses (9)

In the viewer