Definition

The IE SL-LBT-FailureRecoveryConfig-r18 is used to configure the parameters used for detection and cancellation of Sidelink consistent LBT failures for operation with shared spectrum channel access, as specified in TS 38.321 [3].

SL-LBT-FailureRecoveryConfig-r18 ::=    SEQUENCE {
    sl-LBT-FailureInstanceMaxCount-r18      ENUMERATED {n4, n8, n16, n32, n64, n128, spare2, spare1}              OPTIONAL,   -- Need M
    sl-LBT-FailureDetectionTimer-r18        ENUMERATED {ms10, ms20, ms40, ms80, ms160, ms320, spare2, spare1}     OPTIONAL,   -- Need M
    sl-LBT-RecoveryTimer-r18                ENUMERATED {ms10, ms20, ms40, ms80, ms160, ms320, spare2, spare1}     OPTIONAL,   -- Need M
    ...
}

Candidate change requests of v18.2.0

The CRs whose title or cover names this change, strong and likely matches only.

Fields (3)

FieldDescription
sl-LBT-FailureInstanceMaxCount-r18
ENUMERATED {n4, n8, n16, n32, n64, n128, spare2, spare1} · OPTIONAL Need M
since v18.2.0
This field determines after how many LBT failure indications received from the physical layer the UE triggers sidelink LBT failure recovery (see TS 38.321 [3]). Value n4 corresponds to 4, value n8 corresponds to 8, and so on.
sl-LBT-FailureDetectionTimer-r18
ENUMERATED {ms10, ms20, ms40, ms80, ms160, ms320, spare2, spare1} · OPTIONAL Need M
since v18.2.0
Timer for consistent sidelink LBT failure detection (see TS 38.321 [3]). Value ms10 corresponds to 10 ms, value ms20 corresponds to 20 ms, and so on.
sl-LBT-RecoveryTimer-r18
ENUMERATED {ms10, ms20, ms40, ms80, ms160, ms320, spare2, spare1} · OPTIONAL Need M
Timer for consistent sidelink LBT failure cancellation (see TS 38.321 [3]). Value ms10 corresponds to 10 ms, value ms20 corresponds to 20 ms, and so on.